I am a volunteer firefighter and hold a degree in electrical engineering. The shenanigans with their shunt resistors, and ensuing melting cables, is in my view criminal. Any engineer worth their salt would recognize pushing 600W through a bunch of small cables with no contingency if some of them have failed is just asking for trouble. These assholes are going to set someone's house on fire.

I hope they get hit with a class action lawsuit and are forced to recall and properly fix these products before anyone dies as a result of their shoddy engineering.

replies(4): >>44469514 #>>44469723 #>>44469778 #>>44472796 #
ryao ◴[] No.44469723[source]
Has anyone made 12VHPWR cables that replace the 12 little wires with 2 large gauge wires yet? That would prevent the wires from becoming unbalanced, which should preempt the melting connector problem.

As a bonus, if the gauge is large enough, the cable would actually cool the connectors, although that should not be necessary since the failure appears to be caused by overloaded wires dumping heat into the connector as they overheat.

replies(3): >>44469751 #>>44469763 #>>44470380 #
AzN1337c0d3r ◴[] No.44470380[source]
They don't just specify 12 smaller cables for nothing if 2 larger ones will do. There are concerns here with mechanical compatibility (12 wires have smaller allowable bend radius than 2 larger ones with the same ampacity).
replies(1): >>44470568 #
1. kuschku ◴[] No.44470568[source]
One option is to use two very wide, thin insulated copper sheets as cable. Still has a good bend radius in one dimension, but is able to sink a lot of power.