←back to thread

119 points mcswell | 1 comments | | HN request time: 0s | source
Show context
bigattichouse ◴[] No.44454434[source]
A lot of people throw around 5% efficiency for Peltiers, and it's just not true - it depends heavily on the temperature differential and current vs. IMax. You can (with care) drive them >2.0 COP.

This isn't anything like a compressor or heatpump system, but Peltiers get a bad rap... they move heat really well if you're not pushing them to the edge.

Here's a nice chart. At 10k difference and 0.1 current max, you're over 2.5 COP. https://www.meerstetter.ch/customer-center/compendium/71-pel...

replies(4): >>44454564 #>>44455205 #>>44455553 #>>44459681 #
wrigby ◴[] No.44455205[source]
I didn’t know this, and it jumps out to me because 10k is pretty much the exact difference between room temperature and wine fridge tenperature - I wonder if this is actually not a horrible application for peltiers?
replies(2): >>44455363 #>>44456398 #
1. frankus ◴[] No.44456398[source]
I think the gotcha is that you need a beefy heatsink and fan (and power for the fan) to keep the hot side anywhere close to room temperature.