←back to thread

265 points colejohnson66 | 1 comments | | HN request time: 0.38s | source
Show context
deater ◴[] No.44424644[source]
I have to say as a 6502 assembly programmer I have wasted many hours of my life tracking down the same issue in my code (forgetting to put an # in front of an immediate value and thus accidentally doing a memory access instead). Often it's like this case too where things might accidentally work some of the time.

Worse than the floating-bus in this example is when it depends on uninitialized RAM which is often consistent based on DRAM so the code will always work on your machine/emulator but won't on someone else's machine with different DRAM chips (invariably you catch this at a demoparty when it won't run on the party machine and you only have 15 minutes to fix it before your demo is about to be presented)

replies(3): >>44425118 #>>44426179 #>>44426208 #
1. RiverCrochet ◴[] No.44426179[source]
6502 was my first assembly language, and I always thought of instructions like "LDA #2" as "load A with the number 2" versus LDA 2 (load A with what's in memory location 2).