←back to thread

Glubux's Powerwall (2016)

(secondlifestorage.com)
386 points bentobean | 2 comments | | HN request time: 0.406s | source
Show context
scott113341 ◴[] No.43548962[source]
"I made 14 kWh more during lockdown"

https://secondlifestorage.com/index.php?threads/glubuxs-powe...

^ has a wild picture of full setup

replies(3): >>43549067 #>>43549604 #>>43550302 #
orbital-decay ◴[] No.43549604[source]
That fire extinguisher looks ridiculously useless for a setup like this. Good thing it's a separate shed, at least.
replies(6): >>43549800 #>>43549822 #>>43549917 #>>43549946 #>>43551844 #>>43562410 #
1. timewizard ◴[] No.43549822[source]
The fire extinguisher is in the wrong place entirely. If the setup is on fire are you really going to reach _in there_ to grab the extinguisher?

There's no protection over the bus connections. Any falling conductive item is now a spark hazard.

Using spring loaded alligator clips as test leads apparently for monitoring. I hope that's not a permanent configuration.

Everything is bolted down and I see no inline disconnects or even any fusing except on low voltage sections.

There are exhaust fans but I can't tell if there's inlet fans.

From this one picture, which may not be fair, this is not a safe setup. I would feel uncomfortable with this on my property.

replies(1): >>43562494 #
2. hinkley ◴[] No.43562494[source]
Let us hope that all the wires above the battery packs are of the same polarity. I can't tell for sure if that's the case but I hope the two that are closest together are just book-ended.